contact Riegl USA

VZ - 400 - NEW!

Technical Data *(All specs are subject to change while being currently tested)

Rangefinder Performance:
Eye safety class according to:
-IEC60825-1:1993+A1:1997+A2:2001

The following clause applies for instruments delivered into the United States:
-Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.

Long Range Mode
High Speed Mode
Laser Pulse Repetition Rate 2)
100 kHz
300kHz
Effective Measurement Rate 2)
42,000 meas/s
125,000 meas./s
Max Measurement Range 3)
For Natural Targets p ≥ 80%
500 m
300 m
For Natural Targets p ≥ 10%
160 m
100 m
Max. Number of targets per pulse
Practically Unlimited 4)
Practically Unlimited 4)
Accuracy 5) 7)
5 mm
5 mm
Precision5) 7)
3 mm
3 mm
Minimum Range 1.5m
Scanner Performance:
Vertical Line Scan: Max Scan Angle Range: 100°(+60°/-40°)
Min Angle Stepwidth: 0.0024°
Scan Angle Range Total 100° (+60° / -40°)
Scanning Mechanism Rotating Multi Facet Mirror
Scan Speed 10) 3 Lines/s to 120 Lines/s
Angular Stepwidth Δ 9)
Between Consecutive Scan Lines
0.0024° ≤ Δ φ ≤ 0.5°
Angle Measurement Resolution Better 0.0005° (1.8 arcsec)
Inclination Sensors Integrated, For Vertical Scanner Setup Position
Internal Sync Timer Integrated, real time synchronized time stamping of scan data
General Techical Data:
Interfaces: LAN, 10/100/1000 MBit/sec within head
LAN, 10/100 MBit/sec, integrated LAN
USB 2.0
Data Storage Internal 8 GByte flash memory
Power Supply Input Voltage 11-32 V DC
Power Consumption Typ. 65 W
Main Dimensions / Weight 308 mm x 180 mm (length x diameter) / 9.8 kg
Temperature 0°C to +40°C (Operation), - 10°C to +50°C (Storage)
Protection Class IP64, dust and splash-proof

 

Footnotes
1) With Online Waveform Analysis
2) Rounded Values
3) Typical values for average conditions. Maximum range is specified for flat targets with size in excess of the laser beam diameter, perpendicular angle of incidence, and for atmospheric visibility in excess of 23 km. In bright sunlight, the operational range is considerably shorter than under an overcast sky.
4) Details on request.
5) Accuracy is the degree of conformity of a measured quantity to its actual (true) value..
6) Precision, is also called reproducibility, or repeatability, is the degree to which further measurements show the same result.
7) One sigma @ 100 m range under RIEGL test conditions
8) 0.3 mrad correspond to 30 mm increase of beamwidth per 100 m of range.


Main Applications

Architecture/Facade Meas.
As-Built Surveying
Archaeology & Cultural Heritage
City Modeling
Tunnel Surveying
Civil Engineering

Get the Specs

View the technical Specs for this product by clicking the link below:

VZ-400 Technical Specifications